Suppliers of steel products.

tibial lc dcp locking compression locking plate lcp

Comparison of interface contact profiles of a new minimum

In this study, we investigated whether or not a new minimum contact locking compression plate (MC-LCP) can provide advantages over the limited contact dynamic compression plate (LC-DCP) in the context of interface contact area and force. Six matched pairs of cadaveric bones were used for each of three bone types of the humerus, radius and ulna. Effectiveness of Locking Versus Dynamic Compression This study compares the results of the locking compression plate (LCP) and the dy-namic compression plate (DCP) in the treatment of diaphyseal forearm fractures in adults and defines the indications for the use of the LCP. Forty-two patients with diaphyseal forearm fractures were retrospectively analyzed.

Introduction to Plates Flashcards Quizlet

Locking Compression Plate. DCP, LC-DCP, LCP Plates. strongest, allow axial compression, 25 degrees, 7 degrees horizontally. - surgeon is able to compress across fracture using dynamic compression in non locking portion. Variable angle hole. screw holes have four tracks of threads LCP BONE PLATES - Proximal Humerus Locking Plates LCP Combi holes in the plate shaft accept 4.5 mm cortex screws in the dynamic compression unit (DCU) portion, 5.0 mm locking screws in the threaded portion, or a combination of both The preshaped, low-profile plate minimizes potential issues with soft tissues and reduces need for plate contouring LCP BONE PLATES - Proximal Humerus Locking Plates LCP Combi holes in the plate shaft accept 4.5 mm cortex screws in the dynamic compression unit (DCU) portion, 5.0 mm locking screws in the threaded portion, or a combination of both The preshaped, low-profile plate minimizes potential issues with soft tissues and reduces need for plate contouring

LCP Bone Plates - Lateral Tibial Locking Plates

The 3.5 mm LCP Low Bend Medial Distal Tibia Plate is part of the Synthes locking compression plate (LCP) system that merges locking screw technology with conventional plating techniques. The Combi holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking Lcp - LinkedIn SlideShareApr 22, 2016 · Locking compression plate (LCP) dynamic compression unit conical and threaded unit 4. Different types of screws Conventional screws Cortex screw (with or without shaft) Cancellous bone screw (with or without shaft) Locking head screws (LHS) Self-tapping LHS Self-drilling, self-tapping LHS 5. Locking Compression Plates - LCP, DHS & DCS Plates The Locking Compression Plates combines locking screw technology with the advanced design of plates to create constructs for use in comminuted fractures or where deficient bone stock or poor bone quality is encountered.By combining locking screw holes with compression slots, the plates can be used as both locking devices and fracture compression devices.

Locking plate fixation in distal metaphyseal tibial

In 33 fractures a 4.5-mm limited-contact locking compression plate (LC-LCP) was used, 27 fractures were fixed with a metaphyseal LCP and in the remaining 20 fractures, a distal medial tibial LCP was used. Choice of implant was primarily dependent on availability of implants. Locking plate fixation in distal metaphyseal tibial The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures ( n = 41) to maintain the second column of the ankle so as to achieve indirect reduction MIPO IN DISTAL TIBIAL METAPHYSEAL FRACTURES A Jun 30, 2019 · Different implants have been used for MIPO from 4.5mm narrow Dynamic compression plate (DCP), 4.5 mm locking compression plate (LCP) to precontoured distal Tibial LCP (DT-LCP). DCP and LCP require on table contouring whereas in pre-contoured plates this is not required. Locking plates give superior fixation than DCP but are more expensive.

Metaphyseal locking compression plate as an external

This involved placement of a nut on the undersurface of the DCP that turned the device into a fixed angle construction. As a modification of this technique, we introduced the standard locking compression plate (LCP, Synthes BV, Zeist, The Netherlands) as an external fixator, and coined the term supercutaneous plating . In this article, we Metaphyseal locking compression plate as an external This involved placement of a nut on the undersurface of the DCP that turned the device into a fixed angle construction. As a modification of this technique, we introduced the standard locking compression plate (LCP, Synthes BV, Zeist, The Netherlands) as an external fixator, and coined the term supercutaneous plating . In this article, we Part of the DePuy Synthes Locking Compression Plate the 3.5 mm LCP Anterolateral Distal Tibia Plate with locking screws. Note:To verify that independent lag screws will not interfere with plate placement, evaluate placement intraoperatively with AP and lateral fluoroscopic images. 3 Insert plate Optional instrument 324.031 Threaded Plate Holder Open the area as necessary to expose the metaphysis.

Small Fragment Locking CompressionPlate (LCP) System

LC-DCP wrist fusion plates, except for overall length Combi hole dorsal to the capitate allows lagging or locking the capitate to the plate 12 Synthes Small Fragment Locking Compression Plate (LCP) System 2.7 mm 3.5 mm LCP Wrist Fusion Instrument and Implant Set (01.110.051) consists of:01.110.050 LCP Wrist Fusion Instrument Set Part of the DePuy Synthes Locking Compression Plate The 3.5 mm LCP®Anterolateral Distal Tibia Plate is part of the DePuy Synthes LCP System that merges locking screw technology with conventional plating techniques. The plate is stainless steel and features a limited-contact shaft profile.